UPS
ON LINE UPS TECHNICAL SPECIFICATION
| CAPACITY | 20KVA-ONLINE UPS |
| INPUT | 3 PHASE |
| VOLTAGE RANGE | 415V +/- 15% |
| POWER FACTOR | AT 0.8 TYPICAL |
| FREQUENCY | 50 HZ +/- 3 HZ |
| OUTPUT | 3PHASE |
| OUTPUT VOLTAGE | 400V |
| FULL LOAD CURRENT | RATED AT 0.8 P.F. |
| NOMINAL FREQUENCY | 50 HZ +/- 0.5HZ |
| POWER FACTOR | 0.8 P.F. |
| OVER LOAD | 125 % FOR 10 MINUTES / 150 % FOR 1 MINUTE |
| STATIC VOLTAGE REGULATION | +/- 6% FOR 50 % STEP LOAD CHANGE |
| DYNOMIC VOLTAGE REGULATION | +/- 1% OF NOMINAL FOR ALL VARIATIONS OF LINE |
| LOAD | +/- 10 % FOR 10 % TO 100 % STEP LOAD CHANGE |
| WAVEFORM | SINUSOIDAL |
| TOTAL HARMONIC DISTORTION | FOR LINEAR LOAD < 2.5 % FOR NON LINEAR LOADS < 5% |
| INVERTER EFFICIENCY | 85 % TO 93 % ON FULL LOAD DEPENDING ON |
| INVERTER VERSION | IGBT |
| CREST FACTOR | 1: 4 |
| DC CHARACTORISTICS | |
| NOMINAL FLOAT VOLTAGE | DC 312V |
| RECHARGE TIME | 8 – 9 HOURS FOR 100 % |
| RECOVERY BYPASS | MANUAL |
| PROTECTIONS CHARGER | INPUT CIRCUIT BREAKER, CHARGER OVER VOLTAGE, CHARGER OVER CURRENT LIMIT,PHASE FAILURE, ABNORMAL PHASE SEQUENCE. |
| BATTERY | BATTERY LOW CUT OFF / CURRENT LIMIT , HRC FUSE IN BATTERY PATH, BATTERY OVER CHARGE TRIP |
| INVERTER | OVER VOLTAGE / OVER LOAD TRIP,CURRENT LIMIT, SHORT CIRCUIT PROTECTION. |
| INDICATIONS/ METERING | |
| INDICATIONS | MAINS ON, CHARGER ON, BATTERY LOW, INVERTER ON, FAULT/ TRIP. |
| METERING | LCD DISPLAY |
| ENVIRONMENTAL | |
| OPERATING TEMP RANGE | 0 TO 40 DEG CENTIGRADE. |
| RELATIVE HUMIDITY | 95 % NON CONDENCING. |
| MAX OPERATING ALTITUDE | |
| ACOUSTIC NOISE | < 60 db |
TECHNICAL SPECIFICATION FOR SERVO CONTROLLED VOLTAGE STBILIZER
| CAPACITY | 3KVA TO 1000KVA | 1KVA TO 30KVA |
| INPUT | 3 PHASE-4WIRE | 1 PHASE -2WIRE |
| VOLTAGE RANGE | 295V-465V, | 170V-270V, |
| OUTPUT | 3 PHASE | 1 PHASE |
| VOLTAGE REGULATION | 380V/400V/415V +/- 1% | 220V/230V/240V +/- 1% |
| EFFICIENCY | MORE THAN 98% | |
| EFFECT OF POWER FACTOR | NILL | |
| FREQUENCY | 50 HZ +/- 3 HZ | |
| WAVEFORM | SAME AS INPUT WAVE FORM | |
| DUTY CYCLE | CONTINUOUS | |
| MOTOR DRIVE | HEAVY DUTY AC SYNCHRONOUS MOTOR | |
| SYSTEM | UNBALANCED | |
| CONTROL CIRCUIT | IC BASED SOLID STATE CONTROLS & TRIAC SWITCHING FOR MOTOR DRIVE | |
| CORRECTION RATE | 35 V / SECOND/PHASE | |
| PANNEL INDICATION | MAINS ON | |
| OUTPUT ON | ||
| LOW CUT OFF | ||
| HIGH CUT OFF | ||
| METERING |
|
|
| CONTROLS |
|
|
| MAGNETICS | ALL TRANSFORMERS ARE COPPER WOUND AND CRGO LAMINATIONS USED FOR HIGH EFFICIENCY & LOW POWER LOSSES | |
| CLASS OF INSULATION | CLASS “B” | |
| MAXIMUM OUTPUT CURRENT | 100% LOAD for 3.5 Amps PER PHASE | |
| NO LOAD CURRENT | > 0.5% OF RATED CURRENT AT 240V INPUT | |
| TEMPERATURE | 45 DEGREES ABOVE AMBIENT TEMP | |
| NATURE OF COOLING | AIR COOLED/ OIL COOLED | |
| PROTECTIONS | UNDER VOLTAGE , OVER VOLTAGE CUT OFF, SINGLE PHASE PREVENTION, OVERLOAD & SHORT CIRCUIT | |
| INPUT BYPASS CHANGE OVER SWITCH | ||
| STABILIZER STANDARD | AS PER IS 9815 | |
WHY DO WE NEED A SERVO VOLTAGE STABILIZERS?
![]() |
In spite of best efforts, no state electricity board can ensure constant voltage to the customer because of long and inadequate distribution lines and irregular load pattern on distribution transformer. Generally voltage is low during daytime and high during night hours. Moreover on holidays, peak hours, Rainy days and when agricultural and Industrial load is switched off, the Voltage rises sharply, which is more dangerous. |
Voltage fluctuation is a common phenomenon is every part of the country. The industrial units running round the clock usually face the problem of low and high voltage. The industrial units having acute/high failure rate of Electrical & Electronic Equipment such as Bulbs, Tubes, Chokes, Starter, Contactor Coils, Motors, Circuit boards & etc should verify that it may be due to higher voltage.
90% of industrial load is of Electric motors and draw considerably high current at low & high voltages. Operation of any equipments on supply lower than or excess of its rated voltage results in loss of efficiency and over loading which in turn causes the over heating of the windings, resulting in the burn outs and rendering the equipment out of services.
WHAT IS SERVO VOLTAGE STABILIZERS? & WHAT IT DOES?
SERVO CONTROLLED VOLTAGE STABILIZER IS ELECTRONIC DEVICE ABLE TO DELIVER A CONSTANT OUTPUT VOLTAGE IRRESPECTIVE OF ANY CHANGE IN INPUT SUPPLY VOLTAGE.
| KVN POWER manufactures industrial grade Servo Controlled Voltage Stabilizers, which are well known for its reliability & ruggedness. Fully regulated and stable output with a correction speed of 35V/sec even under worst environment and power condition & its ability to handle high starting current are its unique features. It uses Servo motor of high inertia torque, electronic card to control the voltage. High accuracy, high rate of correction, fully solid state control circuit, completely independent manual operation are the special features of SCVS. | ![]() |
|
KEY FEATURES:
- High response, low inertia rugged A. C. servo motor.
- Critically damped response on all loads/supply conditions.
- Energy savings due to high efficiency and superior transformer design.
- High quality raw materials used - prime grade CRGO lamination and high purity electrolytic copper wires/strips used.
- High speeds of correction up to 35V/sec for three phase and 20V/sec for single phase.
- Machine wound variacs with special carbon brushes for enhanced life.
- Simple, systematic construction for dependability and ease of maintenance.
- Solid state control circuitry..
APPLICATIONS:
BANKING SECTOR,MACHINE TOOLS INDUSTRY,COMPUTER SYSTEMS, SATELLITE SYSTEM,TEXTILE INDUSTRY,GRANITE INDUSTRY, HOTELS,COLOR LAB EQUIPMENTS,PHARMACEUTICAL INDUSTRY, MEDICAL EQUIPMENTS, AIR CONDITIONED PLANTS, PAPER MILLS. PRINTING INDUSTRIES,OIL INDUSTRY,COMMUNICATION SYSTEMS, LABORATORY EQUIPMENTS AND OTHER LARGE SCALE INDUSTRIES